The 2400 is the base model of Keithley's 2400-series SourceMeter family, a precision voltage or current source and a 6½-digit meter in one half-rack box. It sources and sinks in all four quadrants, up to 210 V or 1.05 A at 20 W, and its lowest range is 1 µA with 10 pA resolution. Keithley paired it with LabTracer software to make it an I-V curve tracer for diodes, LEDs and transistors. Its firmware dates back to at least 1996, and Tektronix still sells it as a legacy product while steering new buyers to the touchscreen 2450. The family is big. The 2410 goes to 1100 V, the 2420 and 2425 to 3 A, the 2430 pulses to 10 A and the 2440 does 5 A, and a -C suffix adds contact check. This page covers the 2400 and 2400-C.
±21 V at up to ±1.05 A, or ±210 V at up to ±105 mA; 20 W; four-quadrant source and sink
Measure
6½ digits, 0.012% basic accuracy
Lowest current range
1 µA, with 10 pA resolution
Sensing
2-, 4- and 6-wire (guarded) connections
Interfaces
GPIB (SCPI), RS-232 and Trigger Link, all standard
Mains input
100–240 V, 50–60 Hz, detected automatically
Cooling
No fan (the 2410, 2420, 2425, 2430 and 2440 have one)
Weight
3.21 kg
Also listed as
2400 SMU, 2400 Source Meter, Model 2400
Typical eBay ask (Oct 19, 2026)
$3,075–$4,050
Options and accessories
What should come with it
Model 8605 test leads (supplied new)
Kelvin lead sets such as the 5804, 5805, 5808 and 5809
2499-DIGIO digital I/O expander
Check the listing photos and the rear panel against this list, and ask the seller about anything you can’t see. A missing option or probe should come off the price.
What to check
The xdevs 2400 arrived with a dead vacuum fluorescent display and a cracked, sticky front panel, and xdevs says display failures are common. The reading buffer is held by a lithium battery that Keithley rates for three years or more, so expect it to be flat on an older unit.
01Display: Ask for a photo of the display powered on. Every character should be bright and complete.
02Output test: Ask the seller to source 10 V into a known resistor and photo the measured current. The reading should match Ohm's law for that resistor.
03Model: Read the model number on the front panel in the photos. A 2401 stops at 20 V and a 2410 runs to 1100 V, so make sure it's the one you want.
04Front panel: Look at the front panel and keys in the photos. They should be clean and uncracked, with no sticky residue.
05Calibration: Ask for the last calibration certificate. A dated certificate from a named lab, with data, means something, and a sticker or "cal'd" in the title proves little.
06Packing: Ask how it will be packed. It should travel double-boxed with foam all round so the front terminals and rear connectors aren't hit.
Dead displays are common on 2400s, so ask for a photo with every character bright. A reading of it sourcing 10 V into a known resistor checks the rest, since the measured current should match Ohm's law. Most ask $3,075–4,050 delivered, with US sellers inside that and China resellers above it. Calibration dates vary, and one NIST-calibrated unit carries a 2022 date at $4,180.
Listed now
86
For parts
0
Typical ask
$3,075–$4,050
Full range
$2,609–$8,000
★Cheapest
$2,632.71est. delivered
Its photo shows it sourcing 199.999 V with the output on, and it's listed as tested and working with the handle, at $2,633 delivered. The resistor test will confirm the measure side.
Delivered prices include shipping as eBay quoted it to a US address on Oct 19, 2026. Many sellers charge by distance, so your total may differ. eBay shows yours before you pay.
Snapshot
For sale on eBay
8 of 86 listed
Checked . Some may have sold.